We make HUMS work
The (XRDS) identified a fault on the 27th of July. On the 17th of October, the main gearbox was removed from service following chip indicators, 100 flight hours after the XRDS identified the fault. Teardown analysis revealed the source of metal degeneration was from a planetary bearing.